Home
»
Products
»
Geometric measurement technology
»
D630
»
Technical data
Technical data
System
Data transfer
Windows® EasyLink™ program
Measurement distance
See relevant laser transmitter
Temperature range
0–50 °C
Relative humidity
10–95%
Max. displayed error
±1% +1 digit
Weight (complete system)
xx kg
Carrying case
WxHxD: 660x350x160 mm
Display unit
Measurement programs
27 programs
Type of display
Backlit dot matrix LCD
Display size
73x73 mm
Displayed resolution
Changeable: 0.1; 0.01; 0.001 mm. 5; 0.5; 0.05 mils/thou
Battery
4 x 1.5 V R14 (C)
Operating time
24–48 hours continuous, depending on connected equipment
Output port
RS232 for printer and PC communication
Keyboard
Membrane keys with alphanumeric multifunction
Memory
Space for 7,000 measurement points for measuring straightness, for example
Control panel
For measurement value filtering, etc. Unit (mil/thou/mm).
Housing material
Anodized aluminium/ABS plastic
Dimensions
WxHxD: 180x180x45 mm
Weight
1,250 g
Detector D157
Type of detector
2-axis PSD 20x20 mm
Resolution
0.001 mm
Inclinometer resolution
0.1°
Dimensions
Ø40, length 60 mm
Housing material
Brass, stainless steel
Weight
198 g
Laser transmitter D75
Type of laser
Diode laser
Laser wavelength
635–670 nm, visible red light
Laser class
Safety class 2
Laser output power
< 1 mW
Beam diameter
6 mm at aperture
Measurement distance
40 metres
Type of battery
1 x 1.5 V R14 (C)
Operating time/battery
>15 hours
Laser adjustment
2 ways ± 2° (± 35 mm/m)
Housing material
Anodized aluminium
Dimensions
WxHxD: 60x60x120 mm
Weight
700 g
Shaft alignment
Sheave/pulley alignment
Geometric measurement technology
D600
D630
D650
D660
D670
D800
Shims
Custom systems